EZC250N Circuit Breaker Easypact – TMD – 250 A – 3 poles 3d

425.00 د.إ

Model: EZC250N3250
Type:- Circuit Breaker
Brand: SCHNEIDER
Size & Color: Standard,
Brand Origin: India
Product Series: EasyPact

 

Share
SKU 3250

    Circuit breaker Easypact EZC250N – TMD – 250 A – 3 poles 3d

    Specifications
    Main
    range of product :- EasyPact
    Product or component type :- Circuit breaker
    Device short name :- Easypact EZC250N
    circuit breaker name :- Easypact EZC250N
    Device application :- Distribution
    Poles description :- 3P
    Protected poles description :- 3t
    Network type :- DC
    :- AC
    Network frequency :- 50/60 Hz
    [In] rated current :- 250 A at 40 °C
    [Ui] rated insulation voltage :- 690 V AC 50/60 Hz conforming to IEC 60947-2
    [Uimp] rated impulse withstand voltage :- 6 kV conforming to IEC 60947-2
    [Ue] rated operational voltage :- 550 V AC 50/60 Hz conforming to IEC 60947-2
    :- 250 V DC conforming to IEC 60947-2
    Breaking capacity code :- N
    Breaking capacity :- 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
    :- 50 kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2
    :- 50 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
    :- 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2
    :- 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2
    :- 25 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
    :- 25 kA Icu at 400…415 V AC 50/60 Hz conforming to IEC 60947-2
    :- 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
    [Ics] rated service breaking capacity :- 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
    :- 25 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
    :- 10 kA at 125 V DC conforming to IEC 60947-2
    :- 10 kA at 250 V DC conforming to IEC 60947-2
    :- 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
    :- 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
    :- 12.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
    :- 12.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
    Suitability for isolation :- Yes conforming to IEC 60947-2
    utilisation category :- Category A
    Trip unit name :- TM-D
    Trip unit technology :- Thermal-magnetic
    Trip unit rating :- 250 A at 50 °C
    Protection type :- Short-circuit protection
    :- Overload protection
    Pollution degree :- 3 conforming to IEC 60664-1
    :- 3 conforming to IEC 947-1
    Complementary
    control type :- Toggle
    Mounting mode :- Fixed
    mounting support :- Backplate
    Upside connection :- Front
    downside connection :- Front
    Mechanical durability :- 10000 cycles
    Electrical durability :- Category A: 5000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
    Connection pitch :- 35 mm
    local signalling :- Positive contact indication
    Neutral protection setting :- Without protection
    earth-leakage protection :- Without
    height :- 165 mm
    Width :- 105 mm
    Depth :- 60 mm
    Environment
    Standards :- EN/IEC 60947-2
    :- EN/IEC 60947-1
    :- GB/T 14048.2
    IP degree of protection :- IP20 conforming to IEC 60529
    IK degree of protection :- IK07 conforming to IEC 62262
    ambient air temperature for operation :- -25…70 °C
    Ambient air temperature for storage :- -35…85 °C
    Packing Units
    Unit Type of Package 1 :- PCE
    Number of Units in Package 1 :- 1
    Package 1 Height :- 12.0 cm
    Package 1 Width :- 11.0 cm
    Package 1 Length :- 18.2 cm
    Package 1 Weight :- 1.583 kg
    Unit Type of Package 2 :- S03
    Number of Units in Package 2 :- 8
    Package 2 Height :- 30 cm
    Package 2 Width :- 30 cm
    Package 2 Length :- 40 cm
    Package 2 Weight :- 14.09 kg
    Unit Type of Package 3 :- P12
    Number of Units in Package 3 :- 64
    Package 3 Height :- 50 cm
    Package 3 Width :- 80 cm
    Package 3 Length :- 120 cm
    Package 3 Weight :- 124.7 kg

    EasyPact EZC250N is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 25kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 250A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (105mm x 165mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC250N is compliant with international standards (IEC 60947, UL 508) and marine certifications.