PRODUCT DETAILS

product

Schneider MCCB 630A 3P

AED 1700.00

Packing: 1 Nos ( Pieces Per Unit)

Description

Circuit breaker Compact NSX630F - Micrologic 2.3 - 630 A - 3 poles 3d

Specification

Main
range
ComPact
 
product name
ComPact NSX
 
range of product
ComPact NSX400...630
 
device short name
NSX630F
 
product or component type
Circuit breaker
 
device application
Distribution
 
Number of poles
3P
 
protected poles description
3t
 
[In] rated current
630 A at 40 °C
 
[Ue] rated operational voltage
690 V AC 50/60 Hz
 
network type
AC
 
network frequency
50/60 Hz
 
suitability for isolation
Yes conforming to EN/IEC 60947-2
 
utilisation category
Category A
 
[Icu] rated ultimate short-circuit breaking capacity
40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
85 kA at 240 V AC 50/60 Hz conforming to UL 508
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 480 V AC 50/60 Hz conforming to UL 508
20 kA at 600 V AC 50/60 Hz conforming to UL 508
20 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
 
Performance level
F 36 kA 415 V AC
 
trip unit name
Micrologic 2.3
 
trip unit technology
Electronic
 
trip unit protection functions
LSoI
 
control type
Toggle
 
Circuit breaker mounting mode
Fixed
 
Complementary
[Ui] rated insulation voltage
800 V AC 50/60 Hz
 
[Uimp] rated impulse withstand voltage
8 kV
 
[Ics] rated service short-circuit breaking capacity
40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
 
mechanical durability
15000 cycles
 
electrical durability
2000 cycles at 690 V In
6000 cycles at 690 V In/2
4000 cycles at 440 V In
8000 cycles at 440 V In/2
 
mounting support
Backplate
 
upside connection
Front
 
downside connection
Front
 
connection pitch
45 mm
 
protection type
L : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
 
trip unit rating
630 A at 40 °C
 
Long-time pick-up adjustment type Ir (thermal protection)
Adjustable 9 settings
 
[Ir] long-time protection pick-up adjustment range
250...630 A
 
Long-time protection delay adjustment type tr
Fixed
 
[tr] long-time protection delay adjustment range
16 s at 6 x Ir
 
thermal memory
20 minutes before and after tripping
 
Short-time protection pick-up adjustment type Isd
Adjustable 9 settings
 
[Isd] Short-time protection pick-up adjustment range
1.5...10 x Ir
 
Short-time protection delay adjustment type tsd
Fixed
 
Instantaneous protection pick-up adjustment type Ii
Fixed
 
[Ii] instantaneous protection pick-up adjustment range
6900 A
 
earth-leakage protection
Without
 
Number of slots for electrical auxiliaries
6 slot(s)
 
local signalling
Flashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
 
Width (W)
140 mm
 
Height (H)
255 mm
 
Depth (D)
110 mm
 
net weight
6.2 kg